Device Description

Product Name: Flush-Mountable Dimmer v1.8
Brand Name: Z-Wave.Me
Product Line: Düwi modification
Product Code: 054336Z
Product Version:
Product Comment:
Battery Type:
Battery Count:
Description: One paddle dimmer
Inclusion Note: Button triple press
Wakeup Note:
 
Default Image: Not available

Device Data

Hash Weak: 04-11-01
Hash Strong: 0115-1000-0002-03-03-2a-01-08
Manufacturer: Z-Wave.Me (0x0115)
Product Type ID: 0x1000
Product ID: 0x0002
Library Type: 0x03
Protocol Version: 0x03
Protocol Sub Version: 0x2A
Application Version: 0x01
Application Sub Version: 0x08
Basic Class: Slave with routing capabilities
Generic Class: Multilevel Switch
Specific Class: Multilevel Power Switch
Optional Flag: Yes
Listening Flag: Yes
Routing Flag: Yes
Beam Sensor 0
RF Frequency Russia
Certification ID:
Certification Number:
Submitter: poltos
Create time: 2012-06-15 11:21:46
Last changed: 2014-06-24 12:26:10

Implemented Command Classes

Command Class Byte Version Support Control In NIF Secure Non Secure
Basic 0x20 1 Yes Yes Yes No Yes
Multilevel Switch 0x26 2 Yes Yes Yes No Yes
Version 0x86 1 Yes No Yes No Yes
Indicator 0x87 1 Yes No Yes No Yes
All Switch 0x27 1 Yes Yes Yes No Yes
Multi Channel Association 0x8E 2 Yes No Yes No Yes
Configuration 0x70 1 Yes No Yes No Yes
Manufacturer Specific 0x72 1 Yes No Yes No Yes
Protection 0x75 1 Yes No Yes No Yes
Node Naming and Location 0x77 1 Yes No Yes No Yes
Association 0x85 2 Yes No Yes No Yes
Multi Channel 0x60 2 Yes Yes No No Yes
Scene Activation 0x2B 1 Yes Yes Yes No Yes
Scene Actuator Configuration 0x2C 1 Yes No Yes No Yes
Scene Controller Configuration 0x2D 1 Yes No Yes No Yes

Config Parameters

Paramter No. 1 Size 1 Default 3
Name LED mode
Description Set LED indication mode
Type rangemapped
Values
0   ->   Disabled
1   ->   Show switch state
2   ->   Night mode (inverted switch state)
3   ->   Operated by Indicator Command Class
 
Paramter No. 2 Size 2 Default 0
Name Automatically switch off after
Description If not zero, automatically switch off after a user defined time
Type range
Values
0   ->   Disabled
1 - -1   ->   sec
 
Paramter No. 3 Size 1 Default 0
Name What to do on RF off command
Description Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled).
Type rangemapped
Values
0   ->   Switch off
1   ->   Ignore
2   ->   Switch on
3   ->   Switch on if load is off else switch off
 
Paramter No. 16 Size 1 Default 0
Name What to do on button Down press
Description Defines how to interpret button Down press. Depends on "Switch by buttons" parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function.
Type rangemapped
Values
0   ->   Switch off
1   ->   Switch On if load is Off, else switch Off
2   ->   Switch on
 
Paramter No. 4 Size 1 Default 1
Name Ignore start level
Description Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not
Type rangemapped
Values
0   ->   No
1   ->   Yes
 
Paramter No. 5 Size 1 Default 30
Name Dimming speed
Description Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserv bulb life.
Type range
Values
0   ->   Instantly
1 - -1   ->   in 10ms units
 
Paramter No. 6 Size 1 Default 3
Name Dimming long speed
Description Time to dim on button holds and StartLevelChange command (if it has no duration specified).
Type range
Values
1 - -1   ->   seconds
 
Paramter No. 7 Size 1 Default 0
Name Set maximum light level on On click
Description Defines if the dimmer shall set maximum light level on On command. By default on On command dimmer restores last level. This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level
Type rangemapped
Values
0   ->   No
1   ->   If already On
2   ->   Always
 
Paramter No. 8 Size 1 Default 0
Name Baby Dimming time
Description Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands
Type range
Values
0   ->   Disabled
1 - 99   ->   in minutes
 
Paramter No. 9 Size 1 Default 0
Name Target dimming level for Baby Dimming
Description Target level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light.
Type range
Values
0 - -1   ->   %
 
Paramter No. 10 Size 1 Default 50
Name Typical click timeout
Description Typical time used to differenciate click, hold, double and triple clicks
Type range
Values
1 - 100   ->   in 10ms units
 
Paramter No. 11 Size 1 Default 0
Name Invert buttons
Description
Type rangemapped
Values
0   ->   No
1   ->   Yes
 
Paramter No. 12 Size 1 Default 1
Name Switch by buttons
Description If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only.
Type rangemapped
Values
0   ->   No
1   ->   By single press and hold
2   ->   By double press and press-hold
 
Paramter No. 13 Size 1 Default 4
Name Action on button single press or hold
Description Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.
Type rangemapped
Values
0   ->   Disabled
4   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
1   ->   Switch On/Off only (send Basic Set)
2   ->   Switch All
3   ->   Send Scenes
5   ->   Send Preconfigured Scenes
 
Paramter No. 14 Size 1 Default 0
Name Action on button double press or hold
Description Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands
Type rangemapped
Values
0   ->   Disabled
4   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
1   ->   Switch On/Off only (send Basic Set)
2   ->   Switch All
3   ->   Send Scenes
5   ->   Send Preconfigured Scenes
 
Paramter No. 15 Size 1 Default 1
Name Send the following Switch All commands
Description
Type rangemapped
Values
1   ->   Switch off only
2   ->   Switch on only
-1   ->   Switch all on and off
 
Paramter No. 17 Size 1 Default 1
Name Limit minimal light level
Description
Type range
Values
1 - 95   ->   Level limit
 
Paramter No. 18 Size 1 Default 99
Name Limit maximal light level
Description Maximal level should be greater than minial
Type range
Values
0   ->   Work as switch: use off and maximal level
10 - 99   ->   Level limit
 
Paramter No. 19 Size 1 Default 0
Name Switch On on a defined level
Description
Type range
Values
0   ->   Use previous light level
1 - 99   ->   Define light level
 
Paramter No. 51 Size 1 Default 28
Name Pause before pulse
Description NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value.
Type range
Values
5 10/156 ms - 60 10/156 ms   ->  
 
Paramter No. 52 Size 1 Default 28
Name Pause after pulse
Description NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value.
Type range
Values
5 10/156 ms - 60 10/156 ms   ->  
 
Paramter No. 53 Size 1 Default 10
Name Pulse width
Description NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value.
Type range
Values
3 10/156 ms - 20 10/156 ms   ->  
 
Paramter No. 54 Size 1 Default 0
Name Pulse type
Description NB: Do not touch these settings if you are not sure what they mean!
Type rangemapped
Values
0   ->   Long pulse
1   ->   Short pulse
 

Association Groups

Group Number Max Nodes Description
1 14 Single press and hold of up/down buttons
2 14 Double press and press-hold of up/down buttons
3 14 Send Reports on blind state change

Endpoints

Alarm Mappings

 

Back to list, XML