This database is not maintained anymore and will be shut down shortly. Please use the Z-Wave Alliance Product Catalogue as an alternative.
Login

Device Description

Product Name: WALLC-S
Brand Name: Z-Wave.Me
Product Line: Wall Controller
Product Code: Wall Controller
Product Version: 0.9
Product Comment: Secure Wall Controller with 4 buttons
Battery Type: CR2032
Battery Count: 1
Description: Secure Wall Controller with 4 buttons
Inclusion Note: Hit one button for > 1 sec until green/red blinking
Wakeup Note: Simultaneously press four buttons for 5 seconds and then button 2
 
Default Image: Not available

Device Data

Hash Weak: 04-12-02
Hash Strong: 0115-0100-0101-03-03-5c-01-00
Manufacturer: Z-Wave.Me (0x0115)
Product Type ID: 0x0100
Product ID: 0x0101
Library Type: 0x03
Protocol Version: 0x03
Protocol Sub Version: 0x5C
Application Version: 0x01
Application Sub Version: 0x00
Basic Class: Slave with routing capabilities
Generic Class: Remote Switch
Specific Class: Multilevel Remote Switch
Optional Flag: Yes
Listening Flag: No
Routing Flag: Yes
Beam Sensor 0
RF Frequency EU
Certification ID: 14965
Certification Number:
Submitter: cpae
Create time: 2014-06-14 15:31:14
Last changed: 2015-03-03 21:10:44

Implemented Command Classes

Command Class Byte Version Support Control In NIF Secure Non Secure
Battery 0x80 1 Yes No Yes No Yes
Wake Up 0x84 2 Yes No Yes No Yes
Association 0x85 2 Yes No Yes No Yes
Version 0x86 2 Yes No Yes No Yes
Scene Controller Configuration 0x2D 1 Yes No Yes No Yes
Multi Channel Association 0x8E 2 Yes No Yes No Yes
Multi Command Encapsulated 0x8F 1 Yes No Yes Yes Yes
Configuration 0x70 1 Yes No Yes No Yes
Manufacturer Specific 0x72 1 Yes No Yes No Yes
Central Scene 0x5B 1 Yes Yes Yes Yes Yes
Security 0x98 1 Yes Yes Yes No Yes
Z-Wave+ Info 0x5E 1 Yes No Yes No Yes
Device Reset Locally 0x5A 1 Yes No Yes No Yes
Association Group Information 0x59 1 Yes No Yes No Yes
Basic 0x20 1 No Yes Yes Yes Yes
Scene Activation 0x2B 1 No Yes Yes Yes Yes
Multilevel Switch 0x26 1 No Yes Yes Yes Yes
Door Lock 0x62 1 No Yes Yes Yes Yes
Multi Channel 0x60 1 No Yes Yes Yes Yes
All Switch 0x27 1 No Yes No No Yes
Powerlevel 0x73 1 Yes No Yes No Yes

Config Parameters

Paramter No. 1 Size 1 Default 1
Name Button 1 and 3 pair mode
Description In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C.
Type rangemapped
Values
0   ->   Separately
1   ->   In pair without double clicks
2   ->   In pair with double clicks
 
Paramter No. 2 Size 1 Default 1
Name Button 2 and 4 pair mode
Description In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D.
Type rangemapped
Values
0   ->   Separately
1   ->   In pair without double clicks
2   ->   In pair with double clicks
 
Paramter No. 11 Size 1 Default 8
Name Command to Control Group A
Description This parameter defines the command to be sent to devices of control group A when the related button is pressed
Type rangemapped
Values
0   ->   Disabled
1   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2   ->   Switch On/Off only (send Basic Set)
3   ->   Switch All
4   ->   Send Scenes
5   ->   Send Preconfigured Scenes
7   ->   Control Door Lock
8   ->   Central Scene to Gateway
 
Paramter No. 12 Size 1 Default 8
Name Command to Control Group B
Description This parameter defines the command to be sent to devices of control group B when the related button is pressed
Type rangemapped
Values
0   ->   Disabled
1   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2   ->   Switch On/Off only (send Basic Set)
3   ->   Switch All
4   ->   Send Scenes
5   ->   Send Preconfigured Scenes
7   ->   Control Door Lock
8   ->   Central Scene to Gateway
 
Paramter No. 13 Size 1 Default 8
Name Command to Control Group C
Description This parameter defines the command to be sent to devices of control group C when the related button is pressed
Type rangemapped
Values
0   ->   Disabled
1   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2   ->   Switch On/Off only (send Basic Set)
3   ->   Switch All
4   ->   Send Scenes
5   ->   Send Preconfigured Scenes
7   ->   Control Door Lock
8   ->   Central Scene to Gateway
 
Paramter No. 14 Size 1 Default 8
Name Command to Control Group D
Description This parameter defines the command to be sent to devices of control group D when the related button is pressed
Type rangemapped
Values
0   ->   Disabled
1   ->   Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2   ->   Switch On/Off only (send Basic Set)
3   ->   Switch All
4   ->   Send Scenes
5   ->   Send Preconfigured Scenes
7   ->   Control Door Lock
8   ->   Central Scene to Gateway
 
Paramter No. 21 Size 1 Default 1
Name Send the following Switch All commands
Description
Type rangemapped
Values
1   ->   Switch off only
2   ->   Switch on only
-1   ->   Switch all on and off
 
Paramter No. 22 Size 1 Default 0
Name Invert buttons
Description
Type rangemapped
Values
0   ->   No
1   ->   Yes
 
Paramter No. 30 Size 1 Default 1
Name Send unsolicited Battery Report on Wake Up
Description
Type rangemapped
Values
0   ->   No
1   ->   To same node as wake up notification
2   ->   Broadcast to neighbors
 
Paramter No. 25 Size 1 Default 1
Name Blocks wakeup even when wakeup interval is set
Description If the device wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery.
Type rangemapped
Values
0   ->   Wakeup is blocked
1   ->   Wakeup is possible if configured accordingly.
 

Association Groups

Group Number Max Nodes Description
1 10 Lifeline
2 10 Control Group A, controlled by button 1 or single clicks of buttons 1 and 3
3 10 Control Group B, controlled by button 2 or single clicks of buttons 2 and 4
4 10 Control Group C, controlled by button 3 or double clicks of buttons 1 and 3
5 10 Control Group D, controlled by button 4 or double clicks of buttons 2 and 4

Endpoints

Alarm Mappings

 

Back to list, XML